2009/09/13

UE Measurement and Report

(1) Intra-frequency reporting events for FDD
- Event 1a:
A Primary CPICH enters the reporting range
- Event 1b:
A Primary CPICH leaves the reporting range
- Event 1c:
A non-active primary CPICH becomes better than an active primary CPICH
- Event 1d:
Change of best cell
- Event 1e:
A Primary CPICH becomes better than an absolute threshold
- Event 1f:
A Primary CPICH becomes worse than an absolute threshold

(2) Inter-frequency reporting events
- Event 2a:
Change of best frequency
- Event 2b:
The estimated quality of the currently used frequency is below a certain threshold and the estimated quality of a non-used frequency is above a certain threshold.
- Event 2c:
The estimated quality of a non-used frequency is above a certain threshold
- Event 2d:
The estimated quality of the currently used frequency is below a certain threshold
- Event 2e:
The estimated quality of a non-used frequency is below a certain threshold
- Event 2f:
The estimated quality of the currently used frequency is above a certain threshold

(3) Inter-RAT measurements reporting events
- Event 3a:
The estimated quality of the currently used UTRAN frequency is below a certain threshold and the estimated quality of the other system is above a certain threshold.
- Event 3b:
The estimated quality of other system is below a certain threshold
- Event 3c:
The estimated quality of other system is above a certain threshold
- Event 3d:
Change of best cell in other system

Traffic Volume Measurements
- Event 4a:
Transport Channel Traffic Volume becomes larger than an absolute threshold
- Event 4b:
Transport Channel Traffic Volume becomes smaller than an absolute threshold

Quality Measurements
- Event 5a:
A predefined number of bad CRCs is exceeded

UE internal measurements
- Event 6a:
The UE Tx power becomes larger than an absolute threshold
- Event 6b:
The UE Tx power becomes less than an absolute threshold
- Event 6c:
The UE Tx power reaches its minimum value
- Event 6d:
The UE Tx power reaches its maximum value
- Event 6e:
The UE RSSI reaches the UE's dynamic receiver range
- Event 6f:
(FDD) The UE Rx-Tx time difference for a RL included in the active set becomes larger than an absolute threshold
(1.28 Mcps TDD): The time difference indicated by TADV becomes larger than an absolute threshold
- Event 6g:
The UE Rx-Tx time difference for a RL included in the active set becomes less than an absolute threshold

090913r1

沒有留言: